Remosa designs and manufactures manual gate valves for hydrodesulphurisation plants (HDS).
A gate valve is a linear valve that uses a flat closure element perpendicular to the process flow, which slides into the flow steam to provide shutoff.
The gate valve is designed for on-off service in either liquid or gas service (with entrained solid, granules and powders), cryogenic and vacuum service.
Valve body is made from a forged piece of Low Chrome Alloy internally lined with a first buttering layer and a second layer against hydrogen induced cracking (HIC) for a total overlay thickness of 5.5 mm. Disc and seats are hardfaced by Stellite #1 to avoid catalyst erosion.
Remosa's manual gate valves are designed in accordance with:
The valve can be supplied with CE stamp in accordance with the European Pressure Equipment Directive (PED: 97/23/EC) in conformity with Module G and European Directive for Equipment and Protective Systems in potentially Explosive Atmospheres (ATEX: 94/9/EC).